Optical Communication Diagnosis System
High-resolution Optical Link Diagnostic System

High-resolution Optical Link Diagnostic System

Model:OCI

Description

OCI is an ultra-high precision optical link diagnostic instrument based on Optical Frequency Domain Reflectometry (OFDR) technology. With a single measurement, it can achieve comprehensive diagnostics from devices to the entire link. OCI effortlessly locates and identifies macro-bends, connection points, and breakpoints in the optical fiber link, while accurately measuring parameters such as return loss, insertion loss, and spectrum. The event point positioning accuracy of OCI reaches up to 0.1mm. OCI is not only used for optical link diagnostics but also extends its capabilities to distributed optical fiber sensing, enabling high-resolution measurements of strain and temperature.

Features

  • Wavelength range: 1268~1340nm; 1525~1625nm

  • Spatial resolution: 10μm@50m, 20μm@100m

  • Excellent stability, self-calibration without user intervention

  • Measurement range: 100m

  • Extended function for distributed measurement of strain and temperature

  • Software and hardware customization

Applications

Optical communication measurement

  • Optical device and module measurement

  • Fiber length measurement

  • Silicon photonics chip measurement

  • Spectrum and group delay measurement

Distributed Optical Fiber Sensing

  • Structural health monitoring

  • Composite material fatigue testing

  • Strain and temperature testing on automobile structure

  • Strain and temperature field reconstruction for other areas

Parameters

Parameters
Measurement Range1100m
Spatial Resolution20 (10μm@50m)μm
Measurement Time2<12s
Sensitivity-130dB
RL Range-125 ~ 0dB
RL Dynamic Range80dB
IL Dynamic Range18dB
RL/IL Resolution0.05dB
RL/IL Accuracy±0.1dB
Dead ZoneNone
Spectrum
Wavelength Range31268~1340nm; 1525~1625nmnm
Wavelength Resolution0.015pm
Wavelength Accuracy±1.0pm
Group Delay Accuracy1.0ps
Others
Output Optical Power<5mW
Input VoltageAC 220/110V;DC 12V
Power60W
Communication InterfaceUSB
Optical Fiber ConnectorFC/APC
Dimension330 x 350 x 160mm
Weight7.5kg
Storage Temperature0~50
Operating Temperature10~40
Relative Humidity<90%RH
Options4
Interferometer Delay Measurement5
Measurement Range100m
Accuracy60.1mm
Distributed Strain And Temperature Measurement
Sensing Length100m
Spatial Resolution5mm
Strain Accuracy±1.0με
Strain Range±12000με
Temperature Accuracy±0.1
Temperature Range7-200~1200

Note:

  1. Larger measurement range can be customized.

  2. Measurement time is related to the parameter configuration.

  3. If other wavelength is needed, please contact us.

  4. For options, please contact us.

  5. The length result is obtained by setting specific refractive index.

  6. 0.1mm accuracy is obtained in high precision mode.

  7. Temperature range is related to the material property of optical fiber sensor.


All Information given here is reliable to our best knowledge. No responsibility is assumed for possible inaccuracies or omissions. Specifications and external appearances are subject to change without notice.